BRAND | Labom |
Product | GA2610-A4254-M23-N21-T150 |
Description | Resistance Thermometer |
Internal code | PMX4461130 |
Custom code | 90251900 |
Technical specification | GA261 - amp-on technology for temperature measurement on pipes 0 - explosion protection: without A4 - clamping element: for collar installation 254 - for pipe external diameter: 25.4 mm M23 - material insulating sleeve: PVDF (-40...+150 °C) N21 - measuring insert: 1 x PT 100, per DIN EN 60751 class A, 3-wire technology, fast operating T150 - connection head: circular connector M12 x 1 (4 pins) |
Discover the superior quality and performance of the Labom GA2610-A4254-M23-N21-T150 with "Parmex Automatización" SRL in Mexico . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The GA2610-A4254-M23-N21-T150 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of GA2610-A4254-M23-N21-T150 :
At "Parmex Automatización" SRL , we offer the GA2610-A4254-M23-N21-T150 at competitive prices and with the fastest delivery times across Mexico . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose "Parmex Automatización" SRL ?
Get Your Quote Today! Ready to enhance your operations with the GA2610-A4254-M23-N21-T150 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Labom products, "Parmex Automatización" SRL is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
GA2700-HY-A1011-C1025-G11-N3-T150
[RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology Sheet according T4-015 RTD: 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 11 nominal diameter: 1/2 B conical sealing C1 Temperature sensor: ø 6 mm 025 Installation length U1: 25 mm G11 Material wetted parts: stainless steel mat 1.4404 (316L) N3 measuring insert: 1 x Pt 100 (bridged 3-wire) in 4-wire technology T150 electrical connection: Circular connector M 12x1 (4 poles) Range of -50 ... + 200 ° C]
GA2700-HY-A1031-C4025-G11-N2-T150-Z52 PA2430-F12-H1
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 025 installation length U1: 25 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles ) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12: see below measuring range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
GA2700-HY-A1031-C4030-G11-N2-T150-Z52 PA2430-F12-H1
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm, tapered to ø 4 mm 030 installation length U1: 30 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430. ) PA243 TRANSMITTER (for temperature Pt 100), programmed according to data sheet T4-082-1 electrical connection: circular connector M12x1 (4-pole) 0 Type: standard configuration F12: see below measurement range: 0 ... + 150 ° C leakage current with sensor break : 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
GA2700-HY-A1031-C4990-G11-N2-T150-Z52 PA2430-F12-H1
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 990 Einaulänge U1 (in mm): 20 G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100-3-wire system, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12 : see below measurement range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
GA2720-A99-C4025-G11-N2-T150-Z52-W4035-W4020-W5422-W1020 PA2430-F12-H1
(RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology with separate thermowell Explosion protection: without welded thermowell according to drawing B4-CA-00019-z (PG-MB-00025-k))
Measuring range 0 ... 250 ° C
MANOMETER 0 ÷ 25 MPA; Ø100; M20H1 5: ACCURACY CLASS 1.6
1. Scope - 0 ÷ 250 kgf / cm 2. Accuracy class - 1.6 3. Diameter - Ø 100 4. Join-radially by thread M20x1.5
MANOMETER 0 ÷ 40 MPA; Ø 100; M20XL, 5; ¬ CLASS 1.6 ACCURACY.
1. Scope -0 ÷ 400 kgs/sm2 2. Accuracy class - 1.6 3. Diameter-Ø 100 4. Join radial-threaded M20h1 5
MULTIFUNCTION DISPLAY for PASCAL CV
MiniTherm GA 2700 ½” gear (-50…+200°C)
Resistance Thermometer
(MT8 weld G 1/2 100 conically sealing, material stainless steel mat 1.4404 A1 without inspection hole)
CV3110-A1051-F10-H1100-M1-N10-T4-T20-K1085-K80
PRESSURE TRANSMITTER
pascal cv supply 24 v dc
material inspection certificate
PRESSURE GAUGE NG 63 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH51 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A58 display range: 0 ... 10 bar Overload protection: 1.3 times Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 10 Enclosure: IP 65 Process connection back HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A90 display range: -1 ... 5 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 Enclosure: IP 65 with case filling, process connection on the back 30 HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 Enclosure: IP 65 with case filling, process connection on the back 30 HY surface roughness: according to the hygienic design A91 display range: -1 ... 9 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
CI4120-A1061-F2-H21-Y12-T200-K1086 DL2100-A3007-L22
DRUCKMESSUMFORMER PASCAL Ci4 für Druckmittler