BRAND | AEG |
Product | 24SPRE50 |
Description | Thyristor controlled industrial rectifier & battery charger |
Internal code | IMP3424585 |
Weight | 160 |
Technical specification | DC UPS Protect RCS 24V / 50A System configuration System setup Single Operation Battery configuration Individual battery The Protect RCS DC UPS System is a microprocessor based thyristor controlled rectifier. It provides high quality DC power for electronic equipment loads. Mechanical specification Enclosure free standing metal suitable for floor mounting type V2000 cabinet Metal sheet thickness Frame 2 mm Panels 1.5 mm Door 2 mm Protection class (according to IEC 60529) IP21 Painting RAL7035 Ventilation Air inlet in the front doors, front and back cabinet bottom, outlet through rear panel on the top Acoustic noise <66 dB(A) Cable entry from Bottom Dimensions: Height 1200 mm Width 600 mm Depth 800 mm Weight approx. 160 kg Electrical specification Rectifier type: 2 pulse (SCR) thyristor Nominal input voltage 230 VAC Input voltage tolerance ±10% Exceptional variation of the mains input voltage +15%, 20% Number of phases 1 Input frequency 50 Hz Input frequency tolerance ±6% Max. input current (10% mains, in high rate charge and Inom on the output) 13 A AC Rectifier input current total harmonic distortion (THDi) < 66% Input power at nominal voltage and float charge 0,64 Nominal DC output voltage 24V DC Nominal DC output current 50A DC Voltage regulation Static: ±1% • at float charge • 0 100% DC load variation • input mains voltage within the range ±10% • input frequency within the range ±6% • battery temperature within 0°C to 40°C Dynamic: With single LC filter with a battery connected (capacity >5 x nominal current of the rectifier • load variation 10% => 90% : 5% • load variation 90% => 10% : +8% Current regulation +2% at the maximum current level Ripple voltage: Ripple voltage with standard battery capacity of 3x nominal current: without batteries 2.5% RMS typically (max 5%) with batteries 1% RMS Heat losses at rated power 393 W Long term stability for 1000 hours (of output voltage) 0.15% Charger characteristic per IEC 47810: IU High voltage insulation between input/output and electrical earth 2500V AC (With disconnected electronic boards in the rectifier). Insulation resistance with disconnected electronic boards in the Rectifier >200MΩ Input to ground 500V DC Input to output 500V DC Output to ground 500V DC Protection: • Slow start function • Short circuits • Limited at 100% of rated current • Internal DC fuse • Nonvolatile storage of system parameters and user settings • Mains failure shutdown, Rectifier failure shutdown • High voltage DC shutdown • History function for time stamped alarm and system events Battery adjustments (If battery is included in scope of supply, it must appear as a separate line in the quote) Manufacturer Enersys Type HX Capacity 47 Ah Number of cells 0 Number of strings 1 Float charge voltage 0,00 V High rate voltage 0,00 V High rate charge time (range 0150h): 4 h High rate charge timer mode settings Post Commissioning voltage 0,00 V End of discharge voltage 0,00 V Measurements – Alarms Measurements available on LCD display: • AC input voltage • DC charger voltage • DC charger current • DC battery current • Battery capacity • DC load voltage • DC load current Alarm indications: • Mains voltage alarm • Charge fault alarm • Battery voltage alarm • DC voltage alarm • Ground fault +/alarm • Charger current limit alarm • Battery current limit alarm • High charger current alarm • High battery current alarm • high temperature alarm • Temperature sensor error alarm • Internal communication error alarm • Battery test alarm • High battery temperature alarm • Long charge time alarm • No power supply voltage alarm • Battery in operation alarm • Service alarms List of installed items • EMI filter (CE) • Voltage temperature compensation (cable length 30m) • Bridge temperature alarm • AC input protection: Switch • Battery protection: Fuse • Load protection: None • Ground fault (by With GCAU) • Cabinet colour: RAL7035 • Cabinet protection degree: IP21 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for AEG - 24SPRE50 Thyristor controlled industrial rectifier & battery charger number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Mexico Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
KBK II SUSPENSION BRIDGE SHOE
KBK II HANGER BRACKET
KBK II CARASKAL ASMA PLAKASI
(261 SBS interface 400V 261 SBS-interface 400V)
(Graphics ABE 2 GRAPHIC-DOU 2)
power supply module
BATTERY RECTIFIER POWER BLOCK EEC
motor, elec,30kW,1480r/min WO/NT No:25819984 0201 0010 415V,50Hz,3 PH,54 A,225,F,IP 55,1480r/min 30kW, 0.83, B5, 320 kg, DIN VDE 0530, 68 A/6.6 times, 6213 C3 telefunken
Switch
switch
AC/DC Converter
Adapter Lar 831 470.001.203
TIME Adapter LAR 831
(- for normal service - motor power up to 90kW at 400V - rated current up to 170A)
Aptomat
Contactor (230V / 50Hz; 2NO / 2NC)
contactor
Mini-contactor
Aptomat
Aptomat
Type: Protect 8.31 30-400-384-230, Order No. 1000003150th rated power. 30kVA in cosɸ = 0.8 ind, output voltage. 230 V, the UPS system Protect 8. is the successor to the previous UPS Protect 3.33 / 3.31. Classification: VFI SS 111 according to IEC 62040-3
POWER CONTROL UNIT
Tachometer process interface board
ARITHM / LOGIC UNIT
module A500 ALU 061 CPU, CPU 32KRAM 384K use ALU061EN 6390-042.272533 Controller cpu mem mon
MOTOR END COVER(DRIVE END)
LT COOL.PUMP ELC.MOT
Motor, 30 HP; 1500 rpm/min; 6 poles; 380V/50Hz