BRAND | Reo Elektronik |
Product | REOVIB MFS 158 |
Description | frequency converter |
Internal code | IMP4989240 |
Custom code | 85044083 |
Technical specification | Article number 200615801 Input voltage: 115/240 V +/- 15%, 50/60 Hz output voltage: 0... 100/0... 205 V Output current: 4 A output frequency: 35... 140 Hz Protection class: IP 54 version - with input cable and output socket |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Reo Elektronik - REOVIB MFS 158 frequency converter number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Mexico Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
REOTRON EW514 Thyristor Controller
REO control unit
(REO-frequency converter for vibration conveyor devices, input voltage: 110/240 V, +/- 10%, 50/60 Hz Output voltage: 0 ... 95/0 ... 205 V Output current: 12 A (sinusoidal) Frequency range: 5 ... 300 Hz IP 54 (housing version) Execution : - with level control and Vibration amplitude feedback ECCN: N Stat. Product number: 85044082)
(REO-frequency converter for vibration conveyor devices, input voltage: 110/240 V, +/- 10%, 50/60 Hz Output voltage: 0 ... 95/0 ... 205 V Output current: 12 A (sinusoidal) Frequency range: 5 ... 300 Hz IP 54 (housing version) Execution : - with level control and Vibration amplitude feedback ECCN: N Stat. Product number: 85044082)
Input voltage: 110 V, 240 V ± 10% 50/60 Hz Output: 0 ... 100 V / 0 ... 210 V, max. 6 A Oscillation frequency: switchable 50/100 Hz (50 Hz) network 60/120 Hz (60 Hz) network Setpoint: internal via display externally with 0 ... + 10 V, DC 0 (4) ... 20 mA, potentiometer 10 kOhm Release: 24 V, DC or contact (invertible) Level: Int. Supply 24 V DC (Invertible) for PNP sensor ON / OFF: 0 ... 60 sec. Soft start / -auslauf: 0 ... 10 sec. Output clock operation: e.g. Bunker mode - clock on / off 0 ... 60 sec. 5 x Output: 24 V, DC Network status, release status on / off, air valve and Time-Out Connecting conveyor: Han 3 + PE Errors and changes excepted Stand: 13.03.2012 Connection control signals / sensors: M12 Status Relays: changer (250 V, 1 A) Operating temperature: 0 ... 45 ° C IP 54
Schwingweitenmessgerät
Protective Case for SWM 4000
Sensor
Handheld measuring instrument for vibratory feeder
CONTROL UNIT - PHASE OPEN VIBRATING
vibration controller
VIBRATIONS CONTROLLER
POTENTIOMETER
REOTRON EW514 CONTROL DEVİCE
Fuse 6A 250V
Frequency controller
Frequency Controller